← Interactive map
R/S/SGIS CASE STUDYLOS ANGELES

REFLECTIVE SHADE STRUCTURES FOR URBAN HEAT EQUITY

Mapping sun and shade in Skid Row.

Where could shade make Skid Row’s sidewalks more usable on hot days? This study maps how buildings cast shade across the area and uses that pattern to explore reflective screens and street trees.

Study area
Downtown Los Angeles / Skid Row
How the map works
Building heights → sun + shade
Map scope
Sunlight + shade, not people’s locations

Why this study area

Skid Row is a longstanding downtown community shaped in part by city policies that concentrated some homelessness services there and sought to preserve very-low-income residential hotels. The 2024 Greater Los Angeles Homeless Count is a one-night estimate: Los Angeles County reported 3,791 people experiencing homelessness across Skid Row, including 2,112 who were unsheltered. Those neighborhood-wide figures provide context; they do not describe the smaller, project-defined map frame or map individual people. The City identifies Skid Row as an urban heat island with limited trees and shade. We chose Skid Row to ask where shade could make sidewalks more usable during hot weather. UCLA history · LA County count · City heat report

This compact map area makes building heights, sun, and shade easier to inspect at street scale. It does not select an installation location.

Explore the map

  1. 01

    Choose a date + time

    Choose a date and time to see where direct sun reaches the study area.

  2. 02

    Read building heights

    Estimated building heights help model the shade pattern; they are not surveyed measurements.

  3. 03

    Read shade + direct sun

    Dark gray marks modeled building shade. Warm squares show modeled direct sun at the selected time.

  4. 04

    Read map limits

    This map does not identify usable sidewalks, access, people’s locations, heat priority, or comfort.

Map method + source notes

Public USGS 3DEP LiDAR, City building outlines, and optional current OpenStreetMap comparison data provide building-height context for an early study. A historic City sidewalk record is retained in the source notes as a dated planning record; current access is unverified, and it is not displayed in the interactive map.

How screens and trees could work together

Shade performance depends on the material and how it is installed—not the fabric alone. Openness, height, span, direction, and surrounding buildings determine when shade reaches the ground and how it affects airflow, glare, and radiant heat.

01

Placement + orientation

Use direct-sun patterns to identify times and public-space segments worth studying. A proposed screen must cast shade into usable pedestrian space during those periods while accounting for the shape of the street between buildings, trees, awnings, utilities, drainage, sightlines, ownership, and operations.

02

Elevation + span

Mounting height, tilt, edge gaps, and span determine shadow timing, sky view, airflow, wind loading, and drainage. On level ground, the horizontal shift of a point’s shadow ≈ screen height ÷ tan(sun height); it is not the total shadow length of a panel. The overall shade pattern also depends on direction, partial light transmission, surrounding buildings, and terrain.

03

Screen specification

Compare supplier-stated shade percentage, direct and diffused light transmission, knit openness, width, UV resistance, fire documentation, and outdoor-use designation as separate fields. Do not treat a shade percentage as a guaranteed temperature reduction.

What a reflective screen may change

  • Less direct sunlight on people and ground beneath effective shade
  • Changed reflected light and glare, especially from reflective surfaces
  • Lower or higher radiant heat at human height; this needs field measurement
  • Airflow that may be preserved or restricted depending on knit openness and geometry
Material methods + source notes

Outdoor Aluminet O reference range

Green-Tek’s supplied product sheet identifies the open-mesh Aluminet O series for external coverage. These are supplier-stated material specifications—not street-level performance results or installation approval.

Supplier seriesShade %Direct transmissionDiffused transmissionUV resistanceMax. width
O 4038–43%57–62%70%4 years32 ft / 10 m
O 5050–55%45–50%60%4 years32 ft / 10 m
O 6058–63%35–40%56%4 years26 ft / 8 m
O 7070–75%25–30%44%4 years26 ft / 8 m

EyouAgro’s supplied sheet confirms reflective metallized HDPE knit and distinguishes sealed from open structures: its description links open structure to airflow during shading, but provides no comparable transmission values. Green-Tek’s captured O 80 values conflict within the sheet, so that option should not be compared until an updated SKU datasheet is obtained. Before specifying a screen, obtain the selected SKU’s test method, optical properties, fire documentation, warranty, and finished-assembly details.

Measure the assembly, not the catalog claim

Compare shaded and unshaded conditions using shielded air temperature at 1.1 m, globe temperature / mean radiant temperature, relative humidity, wind, surface temperature, shade duration, glare, access, and lived-experience feedback. Pair each intervention point with a comparable unshaded point across repeated hot days.

Shade now, canopy over time

Reflective shade and street trees can be planned together as a staged heat-safety strategy. An elevated Aluminet O screen is a reflective, open mesh—not solid aluminum—and could provide temporary shade while young trees establish. It changes the light and heat reaching leaves and soil while still transmitting light; too much shade can also limit carbon gain and slow growth. The balance depends on species, daily light, irrigation, root volume, soil conditions, and maintenance. This study has not tested tree growth, photosynthesis, or cooling under proposed screens in Skid Row.

Under specific citrus-orchard conditions, aluminized screens have produced cooler leaves and higher midday net carbon uptake in grapefruit, and Aluminet-50 was associated with more vegetative growth. These studies support testing a screen with new trees; they do not predict Skid Row street-tree survival, wind, soil evaporation, transpiration, or air temperature. Grapefruit study · Lemon study · Material description

What a pilot would test

The map informs what to verify next. A pilot would test conditions in the field.

01

Verify walkable space + current access

Confirm the pedestrian surface, current access, and site conditions with field and agency review.

02

Test shade + comfort under paired conditions

Compare shaded and unshaded conditions for shade duration, mean radiant temperature, air temperature, wind, glare, and lived experience.

03

Establish installation + upkeep needs

Define the material, operating, maintenance, and safety conditions that would have to be met before any next step.

Methods + sources

These sources document the completed mapping workflow and inform the next design questions. They do not substitute for site-specific engineering, permitting, or community authorization.

The research below informs three separate evaluation questions: whether shade is usable and accessible (Rose et al.; Reddle Cox et al.), whether the assembly preserves ventilation (Karanja et al.), and how modeled shade differs from measured thermal comfort (Rocca et al.; Díaz-Borrego et al.). These studies support a field-testing plan; they do not establish a Los Angeles cooling prediction.

Map audit + reproducibility

We first used points along street centerlines to estimate corridor shade coverage. A geometry check found that some of those points fell inside building footprints. We retired the coverage percentage and kept the map focused on modeled sun and shade at the selected time. The retired centerline exercise and geometry check remain available for audit; they are not current coverage, access, shade-performance, or feasibility results.

Proposed seasonal analysis

A future seasonal model would compare June 1–October 1 direct-sun exposure at 15-minute intervals from 09:00–18:00 local time. It would use field- and agency-reviewed pedestrian segments—not project-drawn centerlines or the current display grid—and retain source dates, model assumptions, and uncertainty. This is a proposed workflow, not a published seasonal result.

Appendix: five shade layouts to test

These five layout families are design hypotheses for a verified, community-approved pedestrian-use network. They are not coverage, feasibility, or construction results. For a sketch only, a conceptual façade attachment may begin at building height minus 1 m; every four-corner panel would require its own attachment elevations and a structural review.

LayoutSpatial ideaVisual orderSupport / height hypothesisWhat a future analysis would testImportant unresolved condition
01 · Transverse baysRepeated cross-street panels, with panel edges generally perpendicular to the street centerline.Calm, regular “room” sequence.Up to four confirmed attachment points per bay; each point uses its own elevation.Whether regular cross-street cadence reduces repeated sun on the verified pedestrian strip.Opposing façades, clearance, traffic/emergency conflicts, uneven wall heights.
02 · Unified diagonal fieldA linked series of diagonal panels at one common plan bearing.One shared seam angle across a corridor.Façade anchors where feasible; gaps remain explicit.Whether a common diagonal direction improves late-afternoon coverage while keeping a legible field.A preferred angle does not override sun path, drainage, wind, or attachment constraints.
03 · Staggered overlap fieldShorter offset panels overlap in plan rather than spanning every bay as a full rectangle.Ordered shingle/ribbon pattern.Smaller spans and per-corner height projection.Whether overlap reduces short unshaded breaks without a continuous heavy canopy.Edge effects, reflected light, more seams/hardware, maintenance burden.
04 · Longitudinal ribbonsNarrow shade bands follow the pedestrian desire line rather than covering full roadway width.Strong directional continuity.Building-side or independent edge supports, with intentional open zones.Whether shade can protect the walkable path with less material and fewer conflicts.Requires a verified pedestrian path; not valid from a road centerline.
05 · Hybrid support fieldBuilding-supported panels where review permits them, plus separately engineered support modules at discontinuities.A common seam angle and material language, despite different supports.Attachment points only after structural review; gaps use their own support typology or remain unbuilt.Whether continuity can be achieved without falsely assuming every façade is an anchor.This is the most operationally demanding option; ownership, wind, fire, and maintenance govern it.

Optimization here would mean reducing sustained direct-sun exposure on verified public-use space while minimizing unsupported spans, blocking risk, material, visual disorder, and operations burden—not maximizing the shaded area of the study boundary.

STUDY-AREA RATIONALE

UCLA Luskin Center for History and Policy (2021). The Making of a Crisis: A History of Homelessness in Los Angeles.

Supports the careful historical context for Skid Row as a very-low-income downtown community shaped by service and housing policy. It is not evidence about any individual person’s residence or duration in the area.

Los Angeles County Homeless Services & Housing (2024). Resolving Encampments in Skid Row.

Reports the 2024 Count figures cited in the study-area rationale. The aggregate count is contextual only and does not map people or encampments.

City of Los Angeles (2024). Extreme Heat and Skid Row response report.

Supports the City-identified urban-heat and limited-shade context for choosing the study area; it is not a site-specific thermal result.

RESEARCH CONTEXT + LIMITS

Rocca, M., Salvadori, G., Leccese, F., and Bisegna, F. (2025). Textile solar shading systems for reducing the negative impacts of solar radiation in urban areas: a critical review. City and Environment Interactions, 28, 100240.

Review and simplified Mediterranean-city calculations distinguish solar interception, material transmission and thermal or UV outcomes. Supports assembly-specific evaluation; its horizontal continuous-sail assumptions and numerical effects are not transferred to this study.

TREE ESTABLISHMENT · CONTEXT + LIMITS

Cohen, S., Raveh, E., Li, Y., Grava, A., and Goldschmidt, E. E. (2005). Physiological responses of leaves, tree growth and fruit yield of grapefruit trees under reflective shade screens.

Three-summer grapefruit-orchard study of aluminized reflective screens. Supports testing leaf-level conditions; it does not establish all-day carbon gain, lower transpiration, or urban-tree performance.

García-Sánchez, F., Simón, I., Lidón, V., Manera, F. J., Simón-Grao, S., Pérez-Pérez, J. G., and Gimeno, V. (2015). Shade screen increases vegetative growth but not production in ‘Fino 49’ lemon trees.

Four-year established-orchard study of Aluminet-50. Its growth/yield trade-off is not evidence of soil-water effects or street-tree outcomes.

Oivukkamäki, J., et al. (2025). Field integration of shoot gas-exchange and leaf chlorophyll fluorescence measurements to study the long-term regulation of photosynthesis in situ.

Shows how gas exchange and chlorophyll fluorescence can be combined as complementary measures of leaf carbon exchange and photosystem response. The silver-birch field setup does not predict how a Skid Row street tree would respond to a screen.

SCREEN MATERIALS

Green-Tek Aluminet product sheet

Supplier-stated shade percentage, light-transmission, width, UV-resistance, and use notes for Aluminet I, O, and DB product variants.

EyouAgro Aluminet thermal-screen product sheet

Supplier description of reflective metallized HDPE knit, indoor greenhouse use, available roll sizes, and the difference between open and sealed structures.

João Violas Aluminet Net

Supplier material description for a thermo-reflective aluminised mesh and diffused light. It is not independent outcome evidence.

These supplier documents inform procurement questions. They are not independent street-level thermal, fire, or structural certification.